DN150~DN3000 Insertion Electromagnetic Flowmeter
适用介质Liquid
不适用介质Gas
Feature
Applicable sizes 150~3000mm
Operating pressure should be less than 1.6MPa (230 PSI)
Velocity range of 1~10m/s (3-36 fps)
Accuracy is ±2.5%
Hot-tap sensor can be installed and retracted from process piping
Conductivity of measured medium should be more than 50μs/cm
Electrode materials: SUS316L, Hastelloy B, Hastelloy C, Ta, Ti, Pt.
The max. distance between sensor and converter should be less than 50m (165 feet)
Specification
Cable Entry : 2 X PG11 |
Measuring Range : 1 - 10 m/s -bi-direction |
Size : 150-2000mm |
Conductivity : to be more than 50 uS/cm |
Temperature up to 70 deg C |
Connection : Weld, Flange |
Pressure up to 1.6Mpa |
Wetted part : SS304 |
Resistance excitation Coil: 50~70 ohm (std) |
Protection : IP65(convertor) / IP 67(sensor) |
Materials (std) : |
Accuracy : +/-2.5% of reading |
Transmitter housing : Aluminium |
Power supply: 24 VDC, 220 VAC |
Proble : 304SS |
Outputs:4-20mA, Pulse, frequency |
Detector housing : PVC |
Communication:RS485 Modbus(std.),RS232 Modbus, HART,GPRS, Profibus |
Electorde : 316L |
Dimension
在线留言